VH Tower Digital Energy™ VH Series 700 VA - 2 kVA Tower/Rack UPS

The Digital Energy™ VH Series UPS connects between the utility and your critical load, helping ensure that when the utility drops or fails, your load continues to receive a clean, constant and reliable power supply. The VH Series UPS is ideal for protection against utility variances and failures for PC, telecom, laboratory, industrial and critical process loads.
Read More

Specifications Performance Features Key Benefits Applications

Specifications

Model Number UPS25510 UPS25511 UPS25512 UPS25513
Power rating Output Capacity 700VA/630W 1000VA/900W 1500VA/1350W 2000VA/1800W
Power Factor Output Power Factor 0.9 pf
Input Voltage 120V +/- 10% at line input, single phase
Frequency 45 - 66 Hz +/- 5Hz auto-sensing
Input Power Connection Detachable 5-15P Detachable 5-15P Hardwired 5-20P Hardwired 5-20P
Output Voltage (on battery) Pure sine wave at +/- 5% of nominal, -10% of nominal after low battery warning
Voltage (on Mains) 120V, -12%/+10%
Voltage THD < 5% @ 100% resistive load with 80% battery capacity
Frequency (on Battery) 50 or 60 Hz +/- 5% auto-sensing
Voltage Regulation (AVR) AVR automatically increases (boost) output voltage 17% above input voltage if -9% to -25% of nominal.
AVR decreases (buck) output voltage 14% below input voltage if +9% to +25% of nominal.
Output Receptacles -
Power Distribution
(4) 5-15R (4) 5-15R (6) 5-15R (6) 5-15R
Protection & Filtering Spike Protection 780 Joules/6500A
EMI/RF Filter 10dB @ 0.15MHz, 50 dB @ 30 MHz
Overload Protection UPS automatic shutdown if overload exceeds 110% of nominal @ 20 seconds and 125% @ 5 seconds
Transfer Time 4/6 milliseconds (typical), including detection time
Short Circuit Active protection with automatic shutdown
Battery System Type Hot swappable, sealed Valve Regulated Lead Acid (VRLA)
  Battery 12V / 9.0 AH
  Typical Recharge Time 4 hours (to 90% of full capacity)
Protection Automatic self-test and discharge protection, Replace battery indicator
  Battery Quantity 2 pcs 2 pcs 3 pcs 4 pcs
Net Weight (lbs) 30.4 lbs 33.0 lbs 55.0 lbs 66.0 lbs
Dimensions W x D x H (Inches) 5.5" x 17.2" x 8.3" 5.5" x 17.2" x 8.3" 6.7" x 17.7" x 8.9" 6.7" x 17.7" x 8.9"
Communi-cations RS-232 Standard (Detect battery low, schedule UPS on/off, AC Input/Output power status display)
USB Standard
SNMP Optional
Operating System Windows NT, Windows 2000/ME, Windows XP, Linux
Environment Ambient operation 3,500 meters max. elevation, 0-95% RH non-condensing, 0-40° C
Audible noise @ 1 meter < 40 dBA < 45 dBA
Storage condition 15,000 meters max. elevation, 0-95% RH non-condensing, 0-40° C
Certifications UL, cUL, FCC Class A

Battery Runtimes (minutes) ***
VA Standard Internal Battery System
@ 25% Load @ 50% Load @ 75% Load @ 100% Load
700 84 35 20 14
1000 42 17 10 6
1500 42 17 10 6
2000 42 17 10 6

*** Runtimes are estimated